MIBTraps ChapterC
externalAlarmInPort3Alarm 112 major T hetrapissenteverytimeanalarmoccursinthe
ExternalAlarmInputofport#3.Containsasingle
parameterwhichisitsdescription:1‐Description:
ExternalAlarm3‐<UserText>‐Alarm.
externalAlarmInPort4Alarm 113 major T hetrapissenteverytimeanalarmoccursinthe
ExternalAlarmInputofport#4.Contains
asingle
parameterwhichisitsdescription:1‐Description:
ExternalAlarm4‐<UserText>‐Alarm.
swVersionsMismatchFullCompatibilityAlarm 114 warning ThetrapissentifSWversionsmismatchwithfulllink
functionality.Containsasingleparameterwhichisits
description:1‐Description:Softwareversions
mismatch‐fulllinkfunctionality
swVersionsMismatchRestrictedCompatibilityAlarm 115 minor ThetrapissentifSWversions
mismatchwithre stricted
linkfunctionality.Containsasingleparameterwhichis
itsdescription:1‐Description:Softwareversions
mismatch‐restrictedlinkfunctionality
swVersionsMismatchSoftwareUpgrad eRequired 116 major ThetrapissentifSWversionsmismatchandSW
upgradeisrequired.Containsasingleparameter
whichisitsdescription:1‐Description:Software
versionsmismatch‐Softwareupgrade required
swVersionsIncompatible 117 critical The
trapissentifSWversionsareincompatible.
Containsa singleparameterwhichisitsdescription:1‐
Description:SWVersionsincompatible
hssMultipleSourcesDetectedAlarm 118 major Indicatesthatmultiplesyncpulsesourceswere
detected.Containsasingleparameterwhichisits
description:1‐Description:HSSmultiplesyncsources
weredetected.
hssSyncToProperSourceStoppedAlarm 119 major Indicatesthatsynchronizationtoa
propersyncpulse
sourcewasstopped.Containsasinglepar ameter
whichisitsdescription:1‐Description:HSSsyncpulse
‐Down.Thereasonis:%s.%s‐Isthereasonforthe
syncdown.
hssSyncPulseDetectedAlarm 120 major IndicatesthatHSSadditionalsyncpulsewasdetected.
Containsa singleparameterwhichisitsdescription:1‐
Description:
HSSadditionalsyncpulsewasdetected.
tdmBackupAlarm 121 major IndicatesthattheTDMbackuplinkwasactivated.
Containsa singleparameterwhichisitsdescription:1‐
Description:TDMbackupalarm‐backuplinkwas
activated.
linkLockUnauthorizedRemoteODU 122 major IndicatesthattheremoteODUisunauthorized. 
Containsa singleparameterwhichisitsdescription:1‐
Description:UnauthorizedremoteODU
connection
rejected.
linkLockUnauthorizedODU 123 major IndicatesthattheODUisunauthorized.Containsa
singleparameterwhichisitsdescription:1‐
Description:UnauthorizedODUconnectionrejected.
hotStandbyAlarm 124 major Indicatesthatthehotstandbysecondarylinkwas
activated.Containsasingleparameterwhichisits
description:1‐Description:SecondaryLinkIsActive.
sfpInsertion 126 normal Indicatesthatadevicewas
insertedtoSFPPort
sfpPort1DisconnectedAlarm 127 major I ndicatestheSFPport1statuschangedto
disconnected.Containsasingleparameterwhichisits
description:1‐Description:SFPport1statuschanged
todisconnected.
ringRplStateActiveAlarm 128 major RPLstatechangedtoActive.
desiredRatioCanNotBeAppliedAlarm 129 normal IndicatesDesiredUL/DLRAtioCanNotBeApplied.
TableC3:MIBTraps(Sheet4of8)
Name ID Severity Description

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Radwin 2000 C PLUS and is the answer not in the manual?

Radwin 2000 C PLUS Specifications

General IconGeneral
BrandRadwin
Model2000 C PLUS
CategoryRadio
LanguageEnglish

Related product manuals