RADWIN5000HPMPUserManual Release3.5.70 6‐1
Chapter6:
InstallingtheSector
ScopeofthisChapter
Chapter5offeredanoverviewofarunningSectorasmotivationforthetechnicalinstallation
detailssetoutbelow.
AssumingthattheSectorequipmentisinplaceasdescribedinearlierchapters,sector
installationhastwophases:
• ConfiguringandactivatingtheHBS
• BringinguptheHSUs‐configurationandregistration
ThesameRADWINManagerprogramisusedforboththeHBSandtheHSUs.Muchofthe
processiscommontobothtypesofODU.WewillcovertheHBSindetail;fortheHSUswewill
concentrateonthoseitemswhicharedifferent.Inanyevent,wheresetupproceduresare
commonwewi llpointthemout.
ThischaptercoversfixedandnomadicHSUconfigurations.MobileHSUsarecoveredin
Chapter11.
Concepts
AHBSoutofthebox,mustbeconfigure dwith
• BasicRFparameterssuchasfrequencyband,channelbandwidthsandSectorID
• NetworkingparameterssuchasIPaddress,subnetmaskanddefaultgateway
Atthispoint,theHBSisinaninactivestate,poweredup,configurablebutnottransmitting
anything.
Uponactivation,theHBSwillcommencetransmittingandreceivingpacketsrelatedtosector
managementonly‐thatisnoservice.ActivationandDeactivationareeffectedquitesimply
byclickingatogglebutton.
AssumingthattheSectorHSUsaremountedalignedandpoweredup,theHSUswilldiscover
theHBSestablishinglinksformanagementonly.AtthispointtheHSUsmaybemanagedover
theair.