RADWIN5000HPMPUserManual Release3.5.70 144
UsingMorethanOneHSSUnit
Condition1:CablingSequence
1. UptonineODUsmaybeconnectedtothefirstHSSunitusingHSSportsSYNC1,SYNC2,
SYNC3,...uptoSYNC9inorderwithoutleavingemptyports.
2. ThenextavailableSYNCportofthefirstHSSunitshouldbeconnectedtoSYNC10
ofthesecondHSSunitasshowninFigure 144.Intheillustration,thenext
availableportonthefirstHSSunitisSYNC6.
3. ThesecondHSSunitmaybefilledoutwithuptoninemoreODUsinreverseorder.
Thatis,connectSYNC9,SYNC8,SYNC7...asshowninFigure 144.
Figure144:CascadingtwoHSSunits
4. ToaddaafurtherHSSunit:ConnectthenextavailableSYNCportfromthesecond
HSSunitindescendingorder(SYNC5inFigure 144)toSYNC1ofthethirdHSS
unit.
5. ODUsareconnectedtothethirdHSSunitfromSYNC2asshowninFigure 145,in
ascendingorder:
Figure145:CascadingthreeHSSunits