RADWIN5000HPMPUserManual Release3.5.70 8‐1
Chapter8:
ManagingtheSector
ScopeofthisChapter
ThischapterdealswithmanagingthesectorfromtheHBS.ItcoversHBSConfigur ationand
HSUConfigurationfromtheHBS.HSUdirectorover‐the‐airconfigurationisalittledifferent
andiscoveredinChapter9.
AConfigurationwindowisavailableforboththeHBSand theHSUstochangesettingwithout
necessarilydroppingservice.Neverthelesscaremustbeexercisedwhenchangingthem.By
wayofexample,changingantennaparametersforaHSUresultsinaHSUreset.Itisnecessary
howeve rtohavethisfunctionintheConfigurationwindowsinceitisrequiredtoinitiallyset
uptheunit.
TheHBSitselfmaybeconfiguredover‐the‐air:Ascenarioforthisiswherethesectorisback‐
hauledbyonoftheHSUs.Therearenosignificantdifferencesbetweenthetwomethods,
howeve rsomecareisrequired.Ifforexample,youdeactivatetheHBSover‐the‐air,youwill
lockyourselfoutofthesector.
RunningSpectrumViewfromtheHBSmanagerover‐the‐air,willlockyououtfortheduration
oftheSpectrumViewtimeoutperiod.
ConfiguringaHBS
ConfigurationMenuButtons
OpentheConfigurationwindow.