RADWIN5000HPMPUserManual Release3.5.70 1211
HBS
Figure127:Settingtheuppertrafficthreshold
Togetdatafordisplay,clickGetData.Theprocessmaytakeafewseconds.
HereisanextractPerformanceMonitoringreportbasedon15minutesrecording:
Figure128:HBS‐Pe rformanceMonitoringreport‐Validdata
Themeaningofthecolumnheadingsisshowninthefollowingtable:
Table122:HBSPerformanceMonitoringFields
ColumnHeading
Abbreviation
Meaning
Description
Integrity Validdataflag
Greentickforcurrentandvalid;Redcrossfor
invalidateddata(Seeexamplebelow).Notethatthe
PerformanceMonitoringdataisnotvalidifnotallthe
valueswerestored(e.g.,duetoclockchangeswithin
theintervalorpowerupreset)
Date&Time Timestamp
Dataare recorded
every15minutes;thelast30days
ofrecordingsaremaintained.Rolloverisatmidnight.
UAS
Unavailable
Seconds
Secondsinwhichtheinterfacewasoutofservice.
ES Erroredseconds
Thenumberofsecondsinwhichtherewasatleast
oneerrorblock.
SES
SevereErrored
Seconds
Thenumberofsecondsinwhichtheservicequality
waslowasdeterminedbytheBBERthreshold.