RADWIN5000HPMPUserManual Release3.5.70 620
ConfiguringafixedHSUFromtheHBS
Figure64:ActivatedHBSrecognizinginstalledbutunconfiguredHSUs
IftherearetoomanyHSUsfortheTableview,switchtothescrollableListview.
13.IfyouareusingLocalConnection,logoutandlogbackintotheHBSonitsIP
address.
Atthispoint,youareabletoconfiguretheHSUsforservice.
Youmayhav eobservedthatoperatingfrequency5.735GHzshown,isnotwhatwechose
(5.820GHz).TheHBStriestooptimizethefrequencytominimizeinterferenceeff ects.
WenextconfigureandregistertheHSUs.ForfixedHSUsyoucandothisineitherorder.For
nomadicHSUsyoumustdefinetheHSUasNomadicpriortoregistration.Wewillshowthe
methodbelow.OurpreferenceistocarryoutconfigurationfirstforallHSUs.
ConfiguringafixedHSUFromtheHBS
TheHSUactivitiesdescribedinthissection,maybecarriedoutanytime‐regardlessof
whetherornottheHSUisregisteredforserviceornot.Theseactivitiesincludeamongother
things,settingtheLocation,Contact,NameandIPaddress.
TheproceduresinthissectionshouldbecarriedoutforeachfixedHSUinthesector.