RADWIN5000HPMPUserManual Release3.5.70 413
Cablesandconnectors
Cableties
Sealingmaterial
WaterproofingtapesuchasScotch23Tape¾”wide,from3MtoensureIP67compliant
protectionagainst wateranddust
Cablesandconnectors
ODUgroundingcable10AWG
ODUPoEcable(outdoorclass,CAT5e,4twistedpairs,24AWG):
Upto100m.for100BaseTconnection.
Fora1000BaseTconnection(HBSonly)useanODUPoEcablenolongerthan75m.
ExternalCAT5ecablediametershouldbebetween79mmtoensurewaterproof
sealing.
SafetyPracticesandProvisions
PreventingOverexposuretoRFEnergy
ToprotectagainstoverexposuretoRFenergy,installtheODUssoastoprovideandmainta in
minimalseparationdistancesfromallpersons.
Whenthesystemisoperational,avoidstandingdirectlyinfrontoftheantenna.StrongRF
fieldsarepresentwhenthetransmitterison.TheODUmustnotbedeployedinalocation
whereitispossibleforpeopletostandorwalkinadvertentlyinfrontoftheantenna.
Grounding
AllRADWINproductsshouldbegroundedduringoperation.Inaddition:
AllODUsshouldbeearthedbyawirewithdiameterofatleast10AWG.
RADWIN5000HPMPODUsmustbeproperlygroundedtoprotectagainstlightning.Itis
theuser'sresponsibilitytoinstalltheequipmentinaccordancewithSection810ofthe
NationalElectricCode,ANSI/NFPANo.701984orSection54oftheCanadianElectrical
Code.Thesecodesdescribecorrectinstallationproceduresforgroundingoutdoorunits,
masts,leadinwiringanddischargeunits.Italsolaysdownthesizeofgrounding
conductorsandconnectionrequirementsforgroundingelectrodes.RADWIN5000
HPMPODUsmustbegroundedtoaProtectiveEarthinaccordancewiththeLocal
ElectricalRegulations.
Note
For1000BaseT,youshoulduseRADWINsuppliedODUPoEcables,which
guarantees1Gbperformance.RADWINcannotguarantee1Gb
performanceifyouusethirdpartycables.