RADWIN5000HPMPUserManual Release3.5.70 510
TheRADWINManagerLogonConcept
Figure57:LogonwindowshowingSNMPsettings.
YoumaychoosetheSNMPversion.IfyourfirewallblocksSNMPv3messagesandforsecurity
reasonscannotbechangedthemuseSNMPv1.
IfyouareusingTrapAuthentication,entertheUserandPassword.Leavingthesefieldsblank
orincorrect,willnotpreventyoufromloggingon.Youwillnotbeabletoseetrapmessages
directedtothetrapmessageaddressassociatedwithadefineduser.Theallocationand
associationofatrapaddresswithauserisdescribedinChapter8,Management.
IfyouareconnectingthroughtheRNMSservercheck
theRMNSconnectbuttonandenter
yourserverIPaddress.
Thefollowingtablesummarizestheseoptions:
Table56:Usertypes,defaultpasswordsandfunction
UserType
Default
Password
Function
SNMPv1 SNMPv3
Community
Communi
tyString
Password
Default
Value
Observer admin Monitoring ReadOnly public ReadOnly public
Operator admin
Installation,
configuration
ReadWrite netman ReadWrite netman
Installer wireless
Operatorplus
setband
ReadWrite netman ReadWrite netman

Table of Contents