InstallingtheBaseStation
Figure429:Exposingthetackysideofthesealingtape
3.AfterconnectingtheshortCAT5eIDU/ODUcable(providedinthebox)fromthe
ODUtotheunit,tightenthecableglandcapfirmlyandusetheinsulationtape
scotch23tofullycoverbothofthecableglands.
4.ConnectthetapewithtackysideuponthecableglandcapandtheCAT5ecable.
StartatStartPointatthebottomofthecableglandasshowninFigure 430.Finish
atEndPointoftheCAT5ecable,2.5cmaftertheendoftheshrinktubing.Stretch
thetapeandapplyhalfoverlappedtoformgapfreejoint.
Figure430:StartandEndpointsforprotectivetapingtheunit
5.Wraptwolayersofan yscotchvinylplasticelectricaltype(e.gScotchSuper88Vinyl
PlasticTapefrom3M)toprotectthejointsasshowninFigure 431.Ensurethatthe
bottomofthecableglandandtheendoftheCAT5ecablearecoveredwiththe
sealingsplicingtapeandwithvinylplastictape.