EasyManua.ls Logo

Radwin 5000 HPMP - Stage 2: Physical Survey

Radwin 5000 HPMP
518 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
RADWIN5000HPMPUserManual Release3.5.70 33
Stage2:PhysicalSurvey
5.Determineandrecordthecompassbearings betweenHBSandfixedHSUs,relativeto
north.
6.Iftherear eobstructionsbetweenthetwosites,calculatetheFresnelZone(see
Chapter23fordetails).
7.Ifthesiteschosendonotmeetrequirements,consideralternativesites.
8.UsetheLinkBudgetCalculator(ontheCDsuppliedwiththeequipmentorusingthe
RADWINManager)todeterminetheexpectedperformance.
Stage2:PhysicalSurvey
Thephysicalsitesurveyreviewstheenvironmentoftheproposedinstallationlocation,to
ensurethatthesectorsitesaresuitableforthewirelessnetwork.Theresultsofthephysical
sitesurveyshouldberecorded.
Inwhatfollows,ODUmaybeanHBSorafixedHSU:
Toperformaphysicalsurvey:
1.Fromthecompassreadingstakeninthepreliminarysurvey,findtheazimuth(hori
zontalposition)thateachfixedHSUshouldfacetowardstheHBS.
2.Usingbinoculars,locateanyobstructionssuchastalltrees,highbuildings,hillsor
mountains.LookforotherRFtowersbetweenthetwosites.Markthelocationsof
theobstructionsonthemap.
3.DeterminethelocationfortheODUs(havingregardforexistingrooftopinstallations
andtowerspace).Theyshouldbeaboveanyobstructions,consideringtheFresnel
zone(seeChapter23).
4.IfyouneedtoinstallanytypeofODUonatower,makesurethatthetowerisfar
enoughfromoverheadelectric powerlines.
5.Determinealocationfortheindoorequipment;itshouldbeascloseaspossibleto
theODU.Atanexistingsite,thereisprobablyanequipmentroomwithcablerouting
channels.
6.MeasureandrecordthepathlengthofthecablefromeachODUpositiontothe
indoorequipmentroom.
Note
Itisadvisabletogoonaclearday,soyoucanmoreeasilyseeany
obstructionsbetweenthetwosites.
Note
OutdoorCAT5e;Maximumcablelength:100mfor10/100BaseTand75m
for1000BaseT(GbEPoEs)

Table of Contents