Chapter3:
SiteSurvey
PlanningtheSectorSite
Overview
Sectorsiteplanningconsistsofasetofsurveys,whichmustbecarriedoutbeforeany
equipmentisdeployed.Ifforsomereason,theoutcomeofanyofthese surveysisnegative,
HBSorHSUrelocationwillneedtobeconsidered.
ASiteSurveyconsistsofthreestages:
1. Preliminarysurvey‐Theproposedsectorisanalyzedintheofficeusingatopographic
map.YoushoulduseadditionaltoolssuchastheLinkBudgetCalculatorortheRadioPlan
ner.
2. Physicalsurvey‐Thelocationsoftheindoorandoutdoorequipmentaredeterminedon
site.
3. RadioFrequency(RF)survey‐Itis recommendedthat
theinstallationareabescanned
withaspectrumanalyzer,toidentifyRFinterferencesoastodetermineaclearchannelfor
radioinstallation(onsite).
TheSiteSurvey
Introduction
RADWINwirelesslinksmustbeplannedbeforeinstallation.Thedesignatedinstallationsites
mustbeappraisedtodeterminethatthewirelesssystemisabletooperateefficientlyand
provideconnectivitywithoutsignaldegradation.
RADWIN5000HPMPoffersawideoperatingfrequencyrange.A freefrequencychannelmust
bedeterminedwithintheoperatingrange,foroptimumperformance.