RADWIN5000HPMPUserManual Release3.5.70 A‐16
LightningProtector
EMC
LightningProtector
Electrical
Nominaldischargecurrents
ImpulseDischargeCurrent
ImpulseSpark‐over
FCC
CFR47ClassB,Part15,SubpartB
ETSI
EN300386,EN301489‐1,EN301489‐4
CAN/CSA‐CEI/IEC
CISPR22‐04ClassB
AS/NZS
CISPR22‐2004ClassB
CompatibleInterfaces
10/100/1000BaseT
DataRates
Upto1000Mbps
NominalOperationalVoltage
48VDC
MaximumOperationalVoltage
60VDC‐650mA
MaximumContinuouscurrent
1A
Impedance
90to110Ohm
Connectiontype
RJ45CAT5eSTP(shielded)
Pin-out
8wires+shielding
PinsProtected
Allpinsprotected
Responsetime
<5microseconds(withODU)
LinetoLine
500A@8/20μs
LinetoGround
2000A@8/20μs
20000A,8/20μs
1operationminimum
10000A,8/20μs
>10operations
2000A,10/350μs
1operation
200A,10/1000μs
>300operations
200A,10/700μs
>500operations
DCSpark-over±20%@100V/s
150V
100V/μs
350V
1000V/μs
500V