RADWIN5000HPMPUserManual Release3.5.70 6‐9
ConfiguringtheSectoroutoftheBox‐IPAddresses
Figure6‐1:LoggingonwithfactorydefaultIPaddress
Alternatively,youcanlogonusingLocalConnectionwithoutneedtochangeyourNetwork
InterfaceCardaddress:
Figure6‐2:LoggingonwithLocalConnection
Warning
• TheLocalConnectionmethodusesbroadcastpacketsto“discover”
theattachedODU
• IfyoulogonusingLocalConnection,butyourphysicalconnectionis
notlocal(i.e.anythingotherthanadirectconnectionbetweenthe
managingcomputerandthePoEdevice),thenanyconfigurationyou
carryoutmay affectotherlinksinthenetwork.Donotdothis!
• Donotcarryoutthisprocedureusingamultihomedmanagingcom‐
puteralsoconnectedtoanetwork.Itwillfloodthenetworkwith
broadcastpack ets.Further,itwillthrowanyotherlinksonthenetwork
intoInstallationorInactivemode.
• Inanyevent,asaprecaution,defaultlog‐onoverLocalConnectionis
read‐onlymode.ChecktheRead/Writeenableboxtocarryoutinstal‐
lationprocedures.
•Networklogon(IPaddresstotheODU)isrecommended.