RADWIN5000HPMPUserManual Release3.5.70 422
InstallingtheBaseStation
ToinstallaLPUonawalladjacenttoanIDU(PoEorIDUH):
1.Usethesuppliedwall
clamptomountthe
secondLPUasclose
aspossibletothe
indooraccesspoint
totheIDU.
2.GroundtheLPUto
anearthstripusing
thegroundinglug.
3.Removethetop
cableLPUglandcap
togetherwiththe
rubbersealingtube.
4.ThreadtheIDUcable
fromtheupperLPU,throughtheremovedcapfromthepreviousstep.
5.PlugitintothetopoftheLPU.
6.ScrewdownandtightentheLPUcap.
7.Connectthe0.5mCAT5ecabletotheBottomoftheLPU.
8.Connecttheotherend(viatheindooraccesspoint)totheIDU.
9.InsulatebothLPUconnections.Seethenextsection,AdditionalConsiderationsfor
Waterproofing below.
AdditionalConsiderationsforWaterproofing
LightningProtectorsandEthernetRepeaters
Iftheseunitsareinstalledatlocationsheavi lyexposedtoheavydust,rainorcorrosive
moisture (forexample,closetothesea),youshouldprotectthemfurtherasinthefollowing
procedure.Intheremainderofthissection,“unit”referstoeitheraLightningProtectionUnit
oraRepeater.
Tosealaunitag ainstexcessivedustandmoisture:
1.ObtainahighqualitysealingmaterialsuchasScotch23Tape¾”wide,from3Mto
ensureIP67compliantprotectionagainstwateranddust.
2.Cuttwopieceseach25cmlong,ofScotch23splicingtape.Removetheplasticcover
toexposethetackysideofthesealingtapeasshowninFigure 429.