RADWIN5000HPMPUserManual Release3.5.70 629
RegisteringafixedHSUforservice
3.YoumayeditoraddthesiteName,LocationandCoordinates.
4.IfyouareusingDualAntennas,youmaycheckaMIMOMode:SpatialMultiplexing
(default)splitsthedataintotwostreamsontransmissionandrecombinesiton
receptionprovidingmaximumthroughput.Diversitytransmitsthesamedataon
frombothantennasandcheckforcorrectnessonreception.ThechoiceisHSU
specific.ForfurtherdetailsaboutMIMOantennamodes,seeAppendixE.
5.ClicktheEvaluatebutton.Serviceevaluationtakesafewsecondsduringwhichthe
windowisdarkenedandinactive.Uponcompletionyoumayassigntimeslotstothe
HSU: