RADWIN5000HPMPUserManual Release3.5.70 826
EthernetServiceConfiguration
HBSAgingTime
TheHBSworksinBridgeMode.InBridgemodetheODUperformsbothlearningandaging,
forwardingonlyrelevantpack etsoverthesector.TheagingtimeoftheODUisbydefault,300
seconds.
EthernetPortsConfiguration
TheODUEthernetportmodeisconfigurableforlinespeed(10/100/1000BaseT)andduplex
mode(halforfullduplex).
Linespeed1000BaseTisonlyavailableiftheHBSisconnectedtoAGbEPoEdevice.
.
AnAutoDetectfeatureisprovided,wherebythelinespeedandduplexmodearedetected
automaticallyusingautonegotiation.Usemanualconfigurationwhenattachedexternal
equipmentdoesnotsupportautonegotiation.ThedefaultsettingisAutoDetect.
TheiconnexttotheCRCerrorcountmaybeclickedtore setthecountertozero.
ToconfiguretheEthernetMode:
IntheEthernetPortsConfigurationpane,usethedropdownmenutochoosethe
requiredmode.
TransmissionRatio(TxRatio,AsymmetricAllocation))
TheTransmissionRatioshowstheallocationofthroughputbetweendownlinkanduplink
trafficattheHBS.TheTransmissionRatioisnotonlysectorwide:IfyouuseHSS(Chapter13)
tocollocatedseveralHBSs(tocoveradjacentsectors),theymustallusethesame
TransmissionRatio.
Caution
Youshould notreconfiguretheportthatisusedforthemanagingcomputer
connection,sinceawrongconfigurationcancauseamanagement
disconnectionorEthernetservicesinterruption.