RADWIN5000HPMPUserManual Release3.5.70 8‐60
TelnetAccesstotheHSU
Table8‐8:HSUTelnet‐SetImmediateCommands
Command Explanation
setip<ipaddr><subnetMask>
<gateway>
SettheODUIPaddress,subnetmaskandgateway .
TheusermustresettheODUafterthecommand
completion
settrap<index:1‐10><ipaddr>
<port:0‐65535>
Setaspecifictrapfromthetrapstable(e.g.settrap3
192.168..101162)
setreadpw<oldpasswd><passwd> Setthereadaccess password(R ea dCommunity)
setwritepw<oldpasswd><passwd>
Settheread‐writeaccesspassword(Rea d‐Write
Community)
settrappw<oldpasswd><passwd> SetthetrapCommunitystring
setbuzzer
<mode:0=OFF,1=AUTO,2=ON>
Setthebuzzermode
settpc<power:Valuebetween
minimalTxpower,andmaximalTx
power>
SettheODUTxPower.Ifawrongvalueisentered,
bothminandmaxvaluesshallbedisplayedinthe
errorreply
setname<newname> Setthenameofthelink
setlocation<newlocation> Setthenameofthelocation
setcontact<newcontact> Setthenameofthesitemanager
setethernet<port:LAN1>
<mode:AUTO,10H,10F,100H,100F,D
ISABLE>
SetthemodeandspeedoftheEthernetport
reboot
Resetsthe
ODU.Theuseriswarnedthatthe
commandwillresettheODU.AnewTelnetsessionto
theODUmaybeopenedaftertheresetiscomplete.
help Displaystheavailablecommands
Table8‐9:HSUTelnet‐SetCommandsrequiringReset
Command Explanation
setsecId<SectorID> SetnewsectorID‐Resetrequired.