RADWIN5000HPMPUserManual Release3.5.70 1214
HSU
Figure1212:HSU‐Pe rformanceMonitoring‐Validandinvaliddata(3of3)
TheHSUreportcontainsmanymorefieldsthantheHBS.Hereistheirmeaning::
Table123:HSUPerformanceMonitoringFields
ColumnHeading
Abbreviation
Meaning
Description
Integrity Validdataflag
Greentickforcurrentandvalid;Redcrossfor
invalidateddata(Seeexamplebelow).Notethatthe
PerformanceMonitoringdataisnotvalidifnotallthe
valueswerestored(e.g.,duetoclockchangeswithin
theintervalorpowerupreset)
Date&Time Timestamp
Dataarerecordedevery15minutes;thelast30daysof
recordingsaremaintained.Rolloverisatmidnight
UAS
Unavailable
Seconds
Secondsinwhichtheinterfacewasoutofservice
ES
Errored
seconds
Thenumberofsecondsinwhichtherewasatleastone
errorblock.
SES
SevereErrored
Seconds
Thenumberofsecondsinwhichthe
servicequality
waslowasdeterminedbytheBBERthreshold
BBE
Background
BlockError
Thenumberoferroredblocksinaninterval
MinRSL(dBm)
Theminimumofthereceivesignallevel(measuredin
dBm)
MaxRSL(dBm)
Themaximumofthereceivesignallevel(measuredin
dBm)
RSLThresh1(
88dBm)
Thenumber
ofsecondsinwhichtheReceiveSignal
Level(RSL)wasbelowthespecifiedthreshold.