RADWIN5000HPMPUserManual Release3.5.70 142
ConnectinganHSSUnit
Figure141:HSSInterconnectionUnit
ToconnectanODUtoanHSSunit:
1.UnscrewtheprotectivecoverfromtheportmarkedSYNC1.
2.ConnecttheRJ45connectorfromoneendofthepreparedCAT5ecabletoSYNC1.
3.ConnecttheotherendoftheCAT5ecabletotheODUconnectorlabeledSYNC.
4.TightentheprotectivesealthatisonthepreparedcableovertheRJ45connector.
5.RepeatforallODUsthataretobecollocatedatthehubsite.ThenextODUtobe
connectedisinsertedinSYNC1,SYNC2,followedbySYNC3andsoon.
Note
ForasingleHSSunit,ensurethatthecollocatedunitsareconnectedin
sequencefromSYNC1.IfanODUisremovedfromthehubsite,then
allremainingODUsmustbereconnectedtomaintaintheconnectivity.
Youmaycascade(daisychain)twoormoreHSSUnitswithanHSS
cable.Themethodisdescribedindetailbelow.