RADWIN5000HPMPUserManual Release3.5.70 C6
PrivateMIBParameters
PrivateMIBParameters
HBS
TableC2:PrivateMIBParameters‐HBS(Sheet1of33)
Name OID Type
Access
Description
winlink1000OduAdmProductType 1.3.6.1.4.1.4458.1000.1.1.1 DisplayString RO ODUconfigurationdescription.
winlink1000OduAdmHwRev 1.3.6.1.4.1.4458.1000.1.1.2 DisplayString RO ODUHardwareVersion.
winlink1000OduAdmSwRev 1.3.6.1.4.1.4458.1000.1.1.3 DisplayString RO ODUSoftwareVersion.
winlink1000OduAdmLinkName 1.3.6.1.4.1.4458.1000.1.1.4 DisplayString RW LinkName.Achangeiseffectiveimmediately.
winlink1000OduAdmResetCmd 1.3.6.1.4.1.4458.1000.1.1.5 Integer RW ResetCommand.Asetcommandwithavalue
of3willcauseadevicereset.HBSonly:Aset
commandwithavalueof4willcauseadevice
resetfortheentiresector.Thereadvalueis
always0.
winlink1000OduAdmAddres 1.3.6.1.4.1.4458.1000.1.1.6 IPAddress RW ODUIPaddress.Achangeiseffectiveafterreset.
Theparameteriskeptforbackward
compatibility.Usingthealternativeparameter:
winlink1000OduAdmIpParamsCnfgis
recommended.
winlink1000OduAdmMask 1.3.6.1.4.1.4458.1000.1.1.7 IPAddress RW ODUSubnetMask.Achangeiseffectiveafter
reset.Theparameteriskeptforbackward
compatibility.Usingthealternativeparameter:
winlink1000OduAdmIpParamsCnfgis
recommended.
winlink1000OduAdmGateway 1.3.6.1.4.1.4458.1000.1.1.8 IPAddress RW ODUdefaultgateway.Achangeiseffectiveafter
reset.Theparameteriskeptforbackward
compatibility.Usingthealternativeparameter:
winlink1000OduAdmIpParamsCnfgis
recommended.
winlink1000OduAdmBroadcast 1.3.6.1.4.1.4458.1000.1.1.1
0
Integer RW ThisparameterisreservedfortheManager
application providedwiththeproduct.
winlink1000OduAdmHostsTable N/A Trapdestinationstable.Eachtrapdestinationis
definedbyanIPaddressandaUDPport.Upto
10addressescanbeconfigured.
winlink1000OduAdmHostsEntry N/A Trapdestinationstableentry.INDEX{
winlink1000OduAdmHostsIndex}
winlink1000OduAdmHostsIndex 1.3.6.1.4.1.4458.1000.1.1.1
2.1.1
Integer RO Trapdestinationstableindex.
winlink1000OduAdmHostsIp 1.3.6.1.4.1.4458.1000.1.1.1
2.1.2
IPAddress RW TrapdestinationIPaddress.Achangeiseffective
immediately.
winlink1000OduAdmHostsPort 1.3.6.1.4.1.4458.1000.1.1.1
2.1.3
Integer RW UDPportofthetrapdestination.Achangeis
effectiveimmediately.
winlink1000OduAdmHostsSecurity
Model
1.3.6.1.4.1.4458.1000.1.1.1
2.1.4
Integer RW Securitymodelusedforthistrapgeneration.
winlink1000OduAdmHostsUserNam
e
1.3.6.1.4.1.4458.1000.1.1.1
2.1.5
DisplayString RW Usernameusedtogenera tethesnmpv3trap.
winlink1000OduAdmHostsPasswor
d
1.3.6.1.4.1.4458.1000.1.1.1
2.1.6
DisplayString RW Passwordusedtogeneratethesnmpv3trap.
winlink1000OduAdmHostsIPv6 1.3.6.1.4.1.4458.1000.1.1.1
2.1.7
DisplayString RW TrapdestinationIPv6address.Achangeis
effectiveimmediately.
winlink1000OduBuzzerAdminState 1.3.6.1.4.1.4458.1000.1.1.1
3
Integer RW Thisparametercontrolstheactivationofthe
buzzerwhiletheunitisininstallmode.A
changeiseffectiveimmediately.Thevalidvalues
are:disabled(0)enabledAuto(1)
enabledConstantly(2)advancedAuto(3).
winlink1000OduProductId 1.3.6.1.4.1.4458.1000.1.1.1
4
DisplayString RO ThisparameterisreservedfortheManager
application providedwiththeproduct.