RADWIN5000HPMPUserManual Release3.5.70 C12
PrivateMIBParameters
winlink1000OduAirDfsState 1.3.6.1.4.1.4458.1000.1.5.1
9
Integer RO Radardetectionstate.Validvalues:disabled(0)
enabled(1).
winlink1000OduAirAutoChannelSe l
ectionState
1.3.6.1.4.1.4458.1000.1.5.2
0
Integer RO Deprecatedparameter.IndicatingAutomatic
ChannelSelectionavailabilityatcurrentchannel
bandwidth.Validvalues:disabled(0)enabled
(1).
winlink1000OduAirEnableTxPowe r 1.3.6.1.4.1.4458.1000.1.5.2
1
Integer RO IndicatingTransmitpowerconfiguration
enabledordisabled.
winlink1000OduAirMinTxPower 1.3.6.1.4.1.4458.1000.1.5.2
2
Integer RO MinimumTransmitpowerindBm.
winlink1000OduAirMaxTxPowerTab
le
N/A TableofMaximumtransmitpowerperairrate
indBm.
winlink1000OduAirMaxTxPowerEnt
ry
N/A MaximumTransmitpowertableentry.INDEX{
winlink1000OduAirMaxTxPowerIndex}
winlink1000OduAirMaxTxPowerInd
ex
1.3.6.1.4.1.4458.1000.1.5.2
3.1.1
Integer RO Airinterfacerateindex.
winlink1000OduAirMaxTxPower 1.3.6.1.4.1.4458.1000.1.5.2
3.1.2
Integer RO MaximumTransmitpowerindBm.
winlink1000OduAirChannelBandwi
dth
1.3.6.1.4.1.4458.1000.1.5.2
4
Integer RW ChannelbandwidthinKHz.Achangeiseffective
afterreset.
winlink1000OduAirChannelBWTabl
e
N/A ChannelBandwidthstable.
winlink1000OduAirChannelBWEntr
y
N/A ChannelBandwidthtableentry.INDEX{
winlink1000OduAirChannelBWIndex}
winlink1000OduAirChannelBWInde
x
1.3.6.1.4.1.4458.1000.1.5.2
5.1.1
Integer RO ChannelBandwidthindex.
winlink1000OduAirChannelBWAvail 1.3.6.1.4.1.4458.1000.1.5.2
5.1.2
Integer RO ChannelBandwidthavai labilityproduct
specific.Optionsare:Notsupportedsupported
withmanualchannelselectionsupportedwith
AutomaticChannelSelection.
winlink1000OduAirChannelsAdmin
State
1.3.6.1.4.1.4458.1000.1.5.2
5.1.3
DisplayString RO Channels'availabilityperCBW.
winlink1000OduAirChannelBWHSS
ATDDConflictPerCBW
1.3.6.1.4.1.4458.1000.1.5.2
5.1.4
Integer RO IndicationforpossibleLinkdropperCBWdueto
conflictbetweenHSSandATDD.
winlink1000OduAirChannelBWMin
RatioForSupporting
1.3.6.1.4.1.4458.1000.1.5.2
5.1.5
Integer RO MinimalTXratiothatmaybeusedbytheHSM
andstillenableproperoperationofthe
aforementionedCBW.
winlink1000OduAirChannelBWMax
RatioForSupporting
1.3.6.1.4.1.4458.1000.1.5.2
5.1.6
Integer RO MaximalTXratiothatmaybeusedbytheHSM
andstillenableproperoperationofthe
aforementionedCBW.
winlink1000OduAirRFD 1.3.6.1.4.1.4458.1000.1.5.2
6
Integer RO Currentradioframedurationinmicroseconds.
winlink1000OduAirRatesTable N/A AirRateindexestableforcurrentchannel
bandwidth.
winlink1000OduAirRatesEntry N/A AirRateindexestableentry.INDEX{
winlink1000OduAirRatesIndex}
winlink1000OduAirRatesIndex RO AirRateindex.
winlink1000OduAirRatesAvail RO AirRateavailabilitydependingonairinterface
conditions.
winlink1000OduAirDesiredRateIdx 1.3.6.1.4.1.4458.1000.1.5.2
8
Integer RW RequiredAirRateindex.0reservedforAdaptive
Rate.Achangeiseffectiveimmediatelyafter
Setoperationtothemastersidewhilethelink
isup.
winlink1000OduAirLinkDistance 1.3.6.1.4.1.4458.1000.1.5.2
9
Integer RO Linkdistanceinmeters.Avalueof‐1indicates
anillegalvalueandisalsousedwhenalinkis
notestablished.
TableC2:PrivateMIBParameters‐HBS(Sheet7of33)