RADWIN5000HPMPUserManual Release3.5.70 C25
PrivateMIBParameters
winlink1000OduAgnLastEventsEntr
y
N/A Entrycontainingthedetailsoflasttraps.INDEX
{winlink1000OduAgnLastEventsIndex}
winlink1000OduAgnLastEventsInde
x
RO Theindexofthetable
winlink1000OduAgnLastEventsSeve
rity
RO CurrentTrapseverity.
winlink1000OduAgnLastEventsIfInd
ex
RO InterfaceIndexwheretheeventoccurred.Traps
thatarenotassociatedwithaspecific
interfacewillhavethefollowingvalue:65535.
winlink1000OduAgnLastEventsTime
T
RO Timestampofthistrap.Thisnumberisin
secondsfromMidnight January1st1970.
winlink1000OduAgnLastEventsText RO Trapdisplaytext(sameasthetextinthese nt
trap).
winlink1000OduAgnUsersTable N/A SNMPuserstable.Eachuserisdefinedbyname
passwordandprofile.
winlink1000OduAgnUsersEntry N/A SNMPuserstableentry.INDEX{
winlink1000OduAgnUsersIndex}
winlink1000OduAgnUsersIndex RO SNMPuserstableindex.
winlink1000OduAgnUsersUserNam
e
RW SNMPusersusernames.
winlink1000OduAgnUsersPassword RW SNMPuserspasswords.
winlink1000OduAgnUsersProfile RW SNMPusersprofile(1=Disabled2=ReadOnly
3=ReadWrite).
winlink1000OduAgnUsersLastAcces
sTime
RO SNMPuserslastaccesstime.
winlink1000IduAdmProductType RO IDUconfigurationdescription.
winlink1000IduAdmHwRev RO IDUHardwareRevision.
winlink1000IduAdmSwRev RO IDUSoftwareRevision.
winlink1000OduAdmNumOfExterna
lAlarmIn
RO Indicatesthenumberofcurrentlyavailable
ExternalAlarmInputs.
winlink1000OduAdmExternAlarmIn
Table
N/A ThisistheExternalAlarmInputstable.
winlink1000OduAdmExternAlarmIn
Entry
N/A Entrycontainingtheelementsofasingle
ExternalAlarmInput.INDEX{
winlink1000OduAdmExternAlarmInIndex}
winlink1000OduAdmExternAlarmIn
Index
RO ThisvalueindicatestheindexoftheExternal
AlarmInputentry.
winlink1000OduAdmExternAlarmIn
Text
RW ThisfielddescribestheExternalAlarmInput.It
isanoptionalstringofnomorethan64
characterswhichwillbeusedintheevent
beingsentasaresultofachangeinthestatusof
theExternalAlarmInput.DEFVAL{Alarm
Description}
winlink1000OduAdmExternAlarmIn
AdminState
RW ThisvalueindicatesifthisExternalAlarmInput
isenabledordisabled.
winlink1000OduAdmExternAlarmIn
Status
RO Thisvalueindicatesthecurrentstatusofthe
ExternalAlarmInput.
winlink1000IduAdmSN RO IDUSerialNumber
winlink1000IduAdmIduDetectionM
ode
RW Thepar ameterdefineswhethertosend
EthernetframestodetectanIDU.Thevalid
writablevaluesare:userDisabled(3)
userEnabled(4).Achangerequiresaresetand
iseffectiveafterreset.
winlink1000IduAdmMountedTrunks RO NumberofmountedtrunksintheIDU
winlink1000IduAdmLicensedTrunks RO NumberofLicensedTrunksintheIDU
TableC2:PrivateMIBParameters‐HBS(Sheet20of33)
Name OID Type
Access
Description