RADWIN5000HPMPUserManual Release3.5.70 C‐28
PrivateMIBParameters
winlink1000IduEthernetIfTable N/A IDUEthernetInterfacetable.
winlink1000IduEthernetIfEntry N/A IDUEthernetInterfacetableentry.INDEX{
winlink1000IduEthernetIfIndex}
winlink1000IduEthernetIfIndex RO IfIndexcorrespondingtothisInterface.
winlink1000IduEthernetIfAddress RO IDUMACaddress.
winlink1000IduEthernetNumOfLan
Ports
RO NumberofLANinterfacesintheIDU.
winlink1000IduEthernetNumOfSfpP
orts
RO Thenumbe rofSFPinterfacesintheIDU.
winlink1000IduEthernetSfpProperti
es
RO SFPvenforproperties:VendorNamePNand
Revision.
winlink1000IduEthernetGbeSuppor
ted
RO SupportedGigabitEthernetinIDU.
winlink1000IduEthernetOduInError
s
RO Thenumbe rofinboundpacketsthatcontained
errorspreventingthemfrombeingdeliverable
toahigher‐layerprotocol.
winlink1000IduBridgeTpAging RW Timeoutinsecondsforaging.Notethatforthis
parametertobeeffectivetheODUmustbe
configuredtoHUBmode.Achangeiseffective
immediately.
winlink1000IduTdmTxClockAvailStat
es
RO AvailablestatesoftheTDMTransmitClock
Controleachinputstatusisrepresentedbya
bit.Whenthestateisavailablethebitvalueis
1.Whenthestateisunavailablethebitvalue
is0.Theavailablestatesare:bit2=
Transparentbit3=LocalLoopTimedbit
4=
RemoteLoopTimedbit5=LocalInternalbit6
=RemoteInternal
winlink1000IduTdmT xClockDesiredS
tate
RW RequiredstateoftheTDMTransmitClock
Control.Achangeiseffectiveafterre‐activation
oftheTDMservice.
winlink1000IduTdmTxClockActualSt
ate
RO ActualstateoftheTDMTransmitClockControl.
winlink1000IduTdmMasterClockAva
ilOptions
RO AvailableoptionsoftheTDMMasterClock
Controleachinputstatusisrepresentedbya
bit.Whentheoptionisavailablethebitvalue
is1.Whentheoptionisunavai lablethebit
valueis0.Theavailableoptionsare:bit2=
Automaticbit3=Tr unk#1bit4
=Trunk#2bit
5=Trunk#3bit6=Trunk#4Whennooptions
areavailablethereturnedvalueis:1
winlink1000IduTdmMasterClockDes
ired
RW RequiredTDMMasterClock.Achangeis
effectiveafterre‐activationoftheTDMservice.
winlink1000IduTdmMasterClockAct
ual
RO ActualTr unkusedforTDMMasterClock.
winlink1000IduTdmConfigTable N/A IDUTDMLinksConfigurationtable.
winlink1000IduTdmConfigEntry N/A IDUTDMLinksConfigurationtableentry.
INDEX{winlink1000IduTdmConfigIndex}
winlink1000IduTdmConfigIndex RO Tableindex.
winlink1000IduTdmIfIndex RO Linkindexintheinterfacetable.
winlink1000IduTdmLineCoding RW ThisparameterappliestoT1trunksonly.The
parametercontrolsthelinecoding.Settingthe
valuetoeachoftheindicesappliestoall.A
changeiseffectiveafterthenextopenofthe
TDMservice.
TableC‐2:PrivateMIBParameters‐HBS(Sheet23of33)
Name OID Type
Access
Description