EasyManua.ls Logo

Radwin 5000 HPMP - Page 473

Radwin 5000 HPMP
518 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
RADWIN5000HPMPUserManual Release3.5.70 C54
PrivateMIBParameters
winlink1000OduPerfMonAirCurrMa
xRSL
1.3.6.1.4.1.4458.1000.1.6.4.
1.2
Integer RO CurrentMaxReceivedLevelReferencestarting
fromthepresent15minutesperiod.
winlink1000OduPerfMonAirCurrRSL
Thresh1Exceed
1.3.6.1.4.1.4458.1000.1.6.4.
1.3
Gauge RO NumberofsecondsReceiveSignalLevel
exceededtheRSL1thresholdinthelast15
minutes.
winlink1000OduPerfMonAirCurrRSL
Thresh2Exceed
1.3.6.1.4.1.4458.1000.1.6.4.
1.4
Gauge RO NumberofsecondsReceiveSignalLevel
exceededtheRSL2thresholdinthelast15
minutes.
winlink1000OduPerfMonAirCurrMi
nTSL
1.3.6.1.4.1.4458.1000.1.6.4.
1.5
Integer RO CurrentMinTransmitSignalLevelstartingfrom
thepresent15minutesperiod.
winlink1000OduPerfMonAirCurrMa
xTSL
1.3.6.1.4.1.4458.1000.1.6.4.
1.6
Integer RO CurrentMaxTransmitSignalLevelstartingfrom
thepresent15minutesperiod.
winlink1000OduPerfMonAirCurrTSL
Thresh1Exceed
1.3.6.1.4.1.4458.1000.1.6.4.
1.7
Gauge RO NumberofsecondsTransmitSignalLevel
exceededtheTSL1thresholdinthelast15
minutes.
winlink1000OduPerfMonAirCurrBB
ERThresh1Exceed
1.3.6.1.4.1.4458.1000.1.6.4.
1.8
Gauge RO NumberofsecondsBackgroundBlockError
RatioexceededtheBBER1thresholdinthelast
15minutes.
winlink1000OduPerfMonAirInterval
Table
N/A Thistabledefines/keepstheaircountersofthe
lastday(inresolutionof15minintervals).
winlink1000OduPerfMonAirInterval
Entry
N/A ThisisanentryintheIntervalTable.INDEX
{ifIndexwinlink1000OduPerfMonAirIntervalIdx
}
winlink1000OduPerfMonAirInterval
Idx
RO Thistableisindexedperintervalnumber.Each
intervalisof15minutesandtheoldestis96.
winlink1000OduPerfMonAirInterval
MinRSL
RO CurrentMinReceivedLevelReferenceper
interval.
winlink1000OduPerfMonAirInterval
MaxRSL
RO CurrentMaxReceivedLevelReferenceper
interval.
winlink1000OduPerfMonAirInterval
RSLThresh1Exceed
RO NumberofsecondsReceiveSignalLevel
exceededtheRSL1thresholdperinter val.
winlink1000OduPerfMonAirInterval
RSLThresh2Exceed
NumberofsecondsReceiveSignalLevel
exceededtheRSL2thresholdACCESSreadonly
perinterval.
winlink1000OduPerfMonAirInterval
MinTSL
RO CurrentMinTransmitSignalLevelperinterval.
winlink1000OduPerfMonAirInterval
MaxTSL
RO CurrentMaxTransmitSignalLevelperinterval.
winlink1000OduPerfMonAirInterval
TSLThresh1Exceed
RO NumberofsecondsTransmitSignalLevel
exceededtheTSL1thresholdperinterval.
winlink1000OduPerfMonAirInterval
BBERThresh1Exceed
RO NumberofsecondsBackgroundBlockError
RatioexceededtheBBER1thresholdper
interval.
winlink1000OduPerfMonAirDayTabl
e
N/A Thistabledefines/keepstheaircountersofthe
lastmonth(inresolutionofdays).
winlink1000OduPerfMonAirDayEntr
y
N/A ThisisanentryintheDaysTable.INDEX
{ifIndexwinlink1000OduPerfMonAirDayIdx}
winlink1000OduPerfMonAirDayIdx RO ThistableisindexedperDaynumber.EachDay
isof15minutesandtheoldestis96.
winlink1000OduPerfMonAirDayMin
RSL
RO CurrentMinReceivedLevelReferenceperDay.
winlink1000OduPerfMonAirDayMa
xRSL
RO CurrentMaxReceivedLevelReferenceperDay.
winlink1000OduPerfMonAirDayRSL
Thresh1Exceed
RO NumberofsecondsReceiveSignalLevel
exceededtheRSL1thresholdperDay.
TableC3:PrivateMIBParameters‐HSU(Sheet16of33)
Name OID Type
Access
Description

Table of Contents

Related product manuals