RADWIN5000HPMPUserManual Release3.5.70 C‐71
PrivateMIBParameters
winlink1000HsuAirAlignmentLastRe
portRssChain3
RO RSSonchain3.
winlink1000HsuAirAlignmentLastRe
portMcsIndexUp
RO MCSindexofthelinkintheuplinkdirection.
winlink1000HsuAirAlignmentLastRe
portMcsIndexDown
RO MCSindexofthelinkinthedownlinkdirection.
winlink1000HsuAirAlignmentLastRe
portState
RO StateoftheEvaluation1Finishedsuccessfully
2PartialEvaluation(TimeoutExceeded)3
EvaluationAborted(TimeoutExceeded)4
Evaluationaborted(UnstableAntenna)5
Evaluationaborted(SyncLost)6Evaluation
aborted(Externalcommand)7Evaluating.
winlink1000HsuServiceCommandSt
r
1.3.6.1.4.1.4458.1000.4.2.1 DisplayString RW AbilitytoperformspecialcommandintheHSU.
Format(string):OperationParam1Param2....|
ParamN.
winlink1000HsuServiceHsuType 1.3.6.1.4.1.4458.1000.4.2.2 Integer RW HSUtype(1=Fixed2=Stationary3=Mobile4
=Transport)
winlink1000HsuServiceHsuLevel 1.3.6.1.4.1.4458.1000.4.2.3 Integer RW HSUlevel(1..4)
winlink1000HsuEthernetPoESuppor
ted
1.3.6.1.4.1.4458.1000.4.3.1.
1
Integer RO IndicatedifthisHSUhasspecialportforPoE
devices.
winlink1000HsuEthernetPoETempe
rature
1.3.6.1.4.1.4458.1000.4.3.1.
2
Integer RO Holdsthetemperature(Celsius)ofthePOE
component.
winlink1000HsuEthernetPoEEquCo
nsumption
1.3.6.1.4.1.4458.1000.4.3.1.
3
Integer RO Holdstheconsumptionoftheconnected
equipment(milliampere).
winlink1000HsuEthernetPoEEquVol
tage
1.3.6.1.4.1.4458.1000.4.3.1.
4
Integer RO Holdsthevoltageoftheconnectedequipment
(Volt).
winlink1000GeneralTrapDe scription 1.3.6.1.4.1.4458.1000.100.1 DisplayString RO Trap'sDescription.UsedforTrapparameters.
winlink1000GeneralTrapSeverity 1.3.6.1.4.1.4458.1000.100.2 Integer RO Trap'sSeverity.UsedforTrapparameters.
winlink1000GeneralCookie 1.3.6.1.4.1.4458.1000.100.3 DisplayString RW ReservedfortheManagerapplicationprovided
withtheproductusedforsavinguser
preferencesaffectingODUoperation.
winlink1000GeneralEcChangesCoun
ter
1.3.6.1.4.1.4458.1000.100.4 Integer RO Thiscounterisinitialize dto0afteradevice
resetandisincrementeduponeachelement
constantwriteoperationviaSNMPorTelnet.
winlink1000GeneralTelnetSupport 1.3.6.1.4.1.4458.1000.100.5 Integer RW Enable/DisableTelnetprotocol.
winlink1000GeneralWISupport 1.3.6.1.4.1.4458.1000.100.6 Inte ger RW Enable/DisableWebInterfaceprotocol.
MandatoryDisabled‐Nooptiontoenablethe
feature.Mandato ryEnabled‐Nooptionto
disablethefeature.
winlink1000GeneralSNMPSupport 1.3.6.1.4.1.4458.1000.100.7 Integer RW Enable/DisableSNMPprotocols
TableC‐3:PrivateMIBParameters‐HSU(Sheet33of33)
Name OID Type
Access
Description