EasyManua.ls Logo

Radwin 5000 HPMP - Page 493

Radwin 5000 HPMP
518 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
RADWIN5000HPMPUserManual Release3.5.70 C74
MIBTraps
hbsUnregisteredUnsynchronizedHsu 31 normal
IndicatesanunregisteredHSUlostsynchronization.
cableQuality 32 normal 1Gbpsrateisnotsupportedduetobadlinequality.
httpAuthentication 33 normal HT TPAuthenticationFailure.
telnetAuthentication 34 normal TelnetAuthenticationFailure.
tdmServiceAlarm 100 major IndicatesthatTDMServiceisinalarmstate.Containsa
singleparameterwhichisitsdescription:1‐
Description:TDMService‐Alarm.
ethServiceClosed 101 major IndicatesthatEthernetServiceisclosed.Containsa
single
parameterwhichisitsdescription:1‐
Description:EthernetServiceisclosed.
ethServiceNotPermitted 102 major IndicatesthatEthernetServiceisnotpermitted.
Containsasingleparameterwhich isitsdescription:1‐
Description:AvalidIDUcouldnotbedetectedat%s.
Pleasecheckyourconfiguration.%s‐IstheLocalSite
nameorRemoteSite
nameorbothsidesoftheLink.
encryptionAlarm 103 major Indicatesanencryptionkeymismatch.Containsa
singleparameterwhichisitsdescription:1‐
Description:EncryptionStatus‐Failed.NoServicesare
available.
changeLinkPasswordAlarm 104 major Indicatesthatafailurehasoccurredwhileattemptingto
changetheLinkPassword.Containsasingleparameter
whichisitsdescript ion:1
‐Description:Failedto
changetheLinkPasswordat/on:%s.%s‐IstheLocal
SitenameorRemoteSitenameorbothsidesofthe
Link.
externalAlarmInPort1Alarm 105 major Thetrapissenteverytimeanalarmoccursinthe
ExternalAlarmInputofport#1.Containsasingle
parameterwhichisitsdescription:
1‐Description:
ExternalAlarm1‐<UserText>‐Alarm.
externalAlarmInPort2Alarm 106 major Thetrapissenteverytimeanalarmoccursinthe
ExternalAlarmInputofport#2.Containsasingle
parameterwhichisitsdescription:1‐Description:
ExternalAlarm2‐<UserText>‐Alarm.
bitFailedAlarm 107 major Thetrapissentifthereisnowa yto
recoverfromthe
situation.Containstwoparameters:1‐Description:
ODUpowerupbuiltintestfailed.Errorcodeis:%n2‐
%nnumber
wrongConfigurationLoadedAlarm 108 major Thetrapissentifthereisawaytorecoverfromthe
situation.Containstwoparameters:1‐Description:
Wrongconfigurationloaded.Errorcodeis:%n2‐%n
number
lanPort1DisconnectedAlarm 109 major IndicatestheLANport1statuschangedto
disconnected.Containsasingleparameterwhichisits
description:1‐Description:LANport1statuschanged
todisconnected.
lanPort2DisconnectedAlarm 110 major IndicatestheLANport2statuschangedto
disconnected.Containsasingleparameterwhichisits
description:1‐Description:LANport2statuschanged
todisconnected.
mngPortDisconnectedAlarm 111 major Indicates
themanagementportstatuschangedto
disconnected.Containsasingleparameterwhichisits
description:1‐Description:Managementportstatus
changedtodisconnected.
externalAlarmInPort3Alarm 112 major Thetrapissenteverytimeanalarmoccursinthe
ExternalAlarmInputofport#3.Containsasingle
parameterwhichisitsdescription:1‐Description:
External
Alarm3‐<UserText>‐Alarm.
TableC4:MIBTraps(Sheet3of8)
Name ID Severity Description

Table of Contents

Related product manuals