RADWIN5000HPMPUserManual Release3.5.70 56
GettingStartedwiththeRADWINManager
WehaveaddplaceholdersforafurtherthreenomadicHSUs.Thatis,uptofourvehicles
equippedtoworkinthisway,mayoperatesimultaneouslyinthesector.
TostarttheRADWINManager:
1.ConnectthemanagingcomputertotheHBSPoELANport.
2.CheckthatyouhaveconnectivitytotheHBS.Youcandothisbyopeningupa
commandlinesession(Start|Runandthentype,cmd).Atthecommandprompt,
type
ping10.104.50.200
Youshouldseesomethinglikethis:
Table55:
Preconfigured setup - one nomadic HSU
Location Attribute Value Remark
HNU.01.01
IPv4
Address 10.104.50.3
AllcommunicatingHSUsandHBSin
thesamesubnet
NetMask 255.255.0.0
DefaultGateway 10.104.10.21
IPv6
Address 2005:104:50::3
SubnetPrefixLength 32
DefaultGateway 2005:104:20::21
Protocol SNMPv1 CanbesettoSNMPv3orbothv1
Contact Brahms Optional
Name Brahms@HNU.01.01 LocationofContact‐optional
TimeSlots
Downlink 6
Mayvarywithcontext
Uplink 2
UnitSerialNumber P07030E000A0003B
Tip
Chooseyourunitlocationscarefully.Forexample,forthreecollocatedHBSs
eachwith32HSUscovering360°,mattersgetoutofhandveryquicklyif
unitsarepoorlynamed.TheycanalwaysbeidentifiedbytheirIPaddresses,
butthatisapoorsubstituteforeffectivenaming.AURLlikenamingpattern
basedonHBS_n.HSU_yisclearandfamiliartoallInternetusers. Keeping
thenamesIPaddressindependentenablesyoutocopytheentiresector
setuptoadifferentgeographiclocationwithoutIPaddre ssduplication.