112
(1) Time Of Specified Range Measurement
Figure 5.61 Time Of Specified Range Settings
[Range Name]: The name of the range to be measured
[Range]: The range for the Time Of Specified Range Measurement
[Start Address]: Address to start measurement
[End Address]: Address to end measurement
Measures the execution time and the execution count in the range between the start address and end address.
Starts measurement with a detected program prefetch in the range specified between the start and end addresses,
and then stops with a detected program prefetch out of the specified range. Measurement can be restarted with a
detected program prefetch in the specified range. The execution count is incremented every time the program is
prefetched at the end address of the specified range. The execution time measured does not include the time
spent while being called from the specified range.