RL78/F13, F14 CHAPTER 17 LIN/UART MODULE (RLIN3)
R01UH0368EJ0210 Rev.2.10 1182
Dec 10, 2015
URS flag (reception status flag)
The URS flag is set to 1 upon start of reception. During reception, the flag retains 1.
Reception is started when:
ï‚·ï€ the start bit is detected.
The URS flag is cleared to 0 upon end of reception. While reception is halted, the flag retains 0.
Reception is ended when:
ï‚·ï€ the first stop bit is sampled.