RL78/F13, F14 CHAPTER 20 EVENT LINK CONTROLLER (ELC) (RL78/F14 Only)
R01UH0368EJ0210 Rev.2.10 1471
Dec 10, 2015
20.2.2 Timer input select register 0
The timer array unit channels 0 to 3 change the event input from the ELC to the source for each channel. For details, see
6.3.8 Timer input select register 0 (TIS0).
20.2.3 A/D converter mode register 1 (ADM1)
This register has the function of specifying the A/D conversion trigger. A/D conversion is performed by two-bit control and
using the signal by the TAU0 channel 1, event signal by the ELC, or pretimed signal/alarm interrupt signal as triggers. For
details, see 12.3.3 A/D converter mode register 1 (ADM1).
20.2.4 D/A converter mode register (DAM)
This register has the real-time output function, which starts D/A conversion using the event input from the ELC as triggers.
For details, see 13.3.3 D/A converter mode register (DAM).