E1/E20/E2/E2 Lite Additional Document    2. Designing the User System 
R20UT1994EJ0910  Rev.9.10    Page 27 of 59 
Oct.06.23   
<Con ne ction  Examp le of  RESE T 
whe n the Target  MCU is an RL7 8/I 1C with the Ba tte ry 
Ba ckup  Fun ction  in Use
>
(Recom m en ded  Circuit)
 
Figure 2-14  Connection Example of RESET# 
(when the Target MCU is an RL78/I1C with the Battery Backup 
Function in Use) 
 
The following describes points for caution regarding Figure 2-9 to Figure 2-14. 
•  Do not install capacitors, series resistors, or filters on signal lines; if attempted, correct communication may 
not be established. There is an exception, however: capacitors can be inserted between VSS and 
RESET_IN. 
•  The circuits and resistance values listed are recommended but not guaranteed. Determine the circuit design 
and resistance values by taking into account the specifications of the target device and noise.  
•  Securely connect pins 2, 12, and 14 to GND of the user system. These pins are used for electrical 
grounding as well as for monitoring of connection with the user system by the E1/E20/E2/E2 Lite. Securely 
connect both pin 10 and pin 13.