RL78/F13, F14 CHAPTER 15 SERIAL ARRAY UNIT
R01UH0368EJ0210 Rev.2.10 870
Dec 10, 2015
(3) Processing flow (in single-transmission mode)
Figure 15-53. Timing Chart of Slave Transmission (in Single-Transmission Mode)
(Type 1: DAPmn = 0, CKPmn = 0)
Remark m: Unit number (m = 0, 1), n: Channel number (n = 0, 1), p: CSI number (p = 00, 01, 10, 11),
mn = 00, 01, 10, 11
SSmn
SEmn
SDRmn
SCKp pin
SOp pin
Shift
register mn
INTCSIp
TSFmn
STmn
Data transmission (8-bit length)
Data transmission (8-bit length)
Data transmission (8-bit length)
Transmit data 3
Transmit data 2
Transmit data 1
Transmit data 1
Transmit data 2
Transmit data 3
Shift operation
Shift operation
Shift operation