Key Counter Interface Unit
SM 2-75 D023/D025
Installation
7. Cut off the part [C] of the rear cover.
8. Clamp the harness from the counter device with the clamp [D] and put it as shown by
the blue arrow (= x 1).
9. Route the harness from the counter device in the same way as the other harnesses [E]
(= x 3).
10. Connect the harness from the counter device to CN4 on the key counter interface
board.
11. Reattach the IOB bracket (see "Controller Box" in the "Replacement and Adjustment"
section)
12. Reassemble the machine.