EasyManua.ls Logo

Ricoh D025 - After Installing the New Pm Parts

Ricoh D025
1522 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
PM Parts Settings
SM 3-3 D023/D025
Preventive
Maintenance
For the following units, there is a new unit detection mechanism. It is not necessary to reset
PM counters.
PCU
Development unit
Complete fusing unit
Toner Collection Bottle (if full or near-full)
3.2.2 AFTER INSTALLING THE NEW PM PARTS
1. Turn on the main power switch.
2. Output the SMC logging data with SP5-990-004 and check the counter values.
3. Make sure that the PM counters for the replaced units are “0” with SP7-803. If the PM
counter for a unit was not reset, then reset that counter with SP 7-804.
4. Make sure that the exchange counter counts up with SP7-853.
5. Make sure that the counters for the previous units (SP7-906) on the new SMC logging
data list (from step 2 above) are equal to the counters (SP7-803) for these units on the
previous SMC logging data list (the list that was output in the “Before removing the old
parts” section).
6. Make sure that the unit replacement date is updated with SP7-950.

Table of Contents