EasyManua.ls Logo

Ricoh D025 - G3 Switches

Ricoh D025
1522 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Bit Switches
D393 104 SM
4.3.5 G3 SWITCHES
G3 Switch 00 [SP No. 1-105-001]
No FUNCTION COMMENTS
0
1
Monitor speaker during
communication (tx and rx)
Bit 1: 0, Bit 0: 0 = Disabled
Bit 1: 0, Bit 0: 1 = Up to Phase
B
Bit 1: 1, Bit 0: 0 = All the time
Bit 1: 1, Bit 0: 1 = Not used
(0, 0): The monitor speaker is disabled all through
the communication.
(0, 1): The monitor speaker is on up to phase B in
the T.30 protocol.
(1, 0): Used for testing. The monitor speaker is on
all through the communication. Make sure that you
reset these bits after testing.
2
Monitor speaker during
memory transmission
0: Disabled 1: Enabled
1: The monitor speaker is enabled during memory
transmission.
3-5
Not used
Do not change the settings.
6
G3 mode selection for direct
line
0: Off
1:On
1: G3 communication through the direct line is
enabled.
7
Not used
Do not change the settings.
G3 Switch 01 [SP No. 1-105-002]
No FUNCTION COMMENTS
0-1
Not used
Do not change the settings.
2-3
Not used
Do not change the settings.
4
DIS frame length
0: 10 bytes 1: 4 bytes
1: The bytes in the DIS frame after the 4th byte will
not be transmitted (set to 1 if there are
communication problems with PC-based faxes

Table of Contents

Related product manuals