Anti-Condensation Heater (Scanner)
SM 2-83 D023/D025
Installation
2.23 ANTI-CONDENSATION HEATER (SCANNER)
2.23.1 INSTALLATION PROCEDURE
1. Rear cover (see "Rear Cover" in the "Replacement and Adjustment" section)
2. Open the ARDF or platen cover.
3. Glass cover [A] ( x 4)
4. ARDF exposure glass [B]
5. Rear scale [C] ( x 3)
6. Exposure glass with left scale [D]
7. Move the scanner carriage to the right side by rotating the scanner motor [E].
8. Install the heater [F] in the scanner unit ( x 1, hook)
9. Put the connector [G] through the cutout.
10. Connect it to the connector [H] (blue and red cords) in the frame of the machine.
11. Reassemble the machine.