Scanner Unit
D023/D025 4-28 SM
4.5.5 SENSOR BOARD UNIT (SBU)
1. Exposure glass ( p.4-20 "Exposure Glass")
2. SBU cover bracket [A] ( x 9)
3. Original length sensor bracket [B] ( x 1, = x 1)
4. Sensor board unit [C] ( x 4, Grand screw x 1, x 2, = x 2)
When reassembling
Adjust the following SP modes after you replace the sensor board unit:
SP4–008 (Sub Scan Mag): See "Image Adjustment: Scanning".
SP4–010 (Sub Mag Reg.): See "Image Adjustment: Scanning".
SP4–011 (Main Scan Reg): See "Image Adjustment: Scanning".
SP4–688 (DF: Density Adjustment): Use this to adjust the density level if the ID of
outputs made in the DF and Platen mode is different.