Bridge Unit (D386)
SM 2-49 D023/D025
Installation
2.13.2 INSTALLATION PROCEDURE
Unplug the copier power cord before starting the following procedure.
1. If you will install the 1-bin tray (D414) in the machine, install the 1-bin tray before
you install the bridge unit (D386). This will make it easier for you to do the
following procedure.
2. If you will install a finisher (B408 or B793) in the machine, install the finisher
after you install the bridge unit (D386).
1. Remove all tapes.
2. If the sensor feeler [A] is out, fold it into the machine.
3. Open the right door of the machine.
4. Remove the inner tray [B].
5. Remove the front right cover [C] ( x 1).
6. Remove the connector cover [D] ( x 1).

Table of Contents