SM Appendix 3-71 D023/D025
Appendix
Service Call
Conditions
3.1.9 SC8XX: OVERALL SYSTEM
No. Type Details (Symptom, Possible Cause, Troubleshooting Procedures)
Energy saving I/O sub-system error
The energy saving I/O sub-system detects an error.
Controller board defective
816
CTL
D
Replace the controller board.
No. Type Details (Symptom, Possible Cause, Troubleshooting Procedures)
Fatal kernel error
819
CTL
C
Due to a control error, a RAM overflow occurred during system
processing. One of the following messages was displayed on the
operation panel.
[0x5032] HAIC-P2 error
[0x5245] vm_pageout: VM is full
[0x5355] L2 status time out
[554C] USB error
System program defective
Controller board defective
Optional board defective
Replace controller firmware

Table of Contents