Bit Switches
D393 114 SM
4.3.6 G3-2/3 SWITCHES
These switches require an optional G3 interface unit.
G3-3 switches are the same as for G3-2 switches.
G3-2 Switch 00 [SP No. 1-106-001]
No FUNCTION COMMENTS
0-1
Monitor speaker during
communication (tx and rx)
Bit 1: 0, Bit 0: 0 = Disabled
Bit 1: 0, Bit 0: 1 = Up to Phase
B
Bit 1: 1, Bit 0: 0 = All the time
Bit 1: 1, Bit 0: 1 = Not used
(0, 0): The monitor speaker is disabled all through
the communication.
(0, 1): The monitor speaker is on up to phase B in
the T.30 protocol.
(1, 0): Used for testing. The monitor speaker is on
all through the communication. Make sure that you
reset these bits after testing.
2
Monitor speaker during
memory transmission
0: Disabled 1: Enabled
1: The monitor speaker is enabled during memory
transmission.
3-6
Not used
Do not change the settings.
G3-2 Switch 01 [SP No. 1-106-002]
No FUNCTION COMMENTS
0-3
Not used
Do not change the settings.
4
DIS frame length
0: 10 bytes, 1: 4 bytes
1: The bytes in the DIS frame after the 4th byte will
not be transmitted (set to 1 if there are
communication problems with PC-based faxes
which cannot receive the extended DIS frames).
5
Not used
Do not change the setting.
6
CED/ANSam transmission
0: Disabled
1: Enabled
Do not change this setting, unless the
communication problem is caused by the
CED/ANSam transmission.