Bit Switches
D393 112 SM
ITU-T T.30 recommendation: The first line should
come within 5 s of CFR.
7
Not used
Do not change the settings.
G3 Switch 0B - Not used (do not change the settings).
G3 Switch 0C - Not used (do not change the settings)
G3 Switch 0D - Not used (do not change the settings).
G3 Switch 0E [SP No 1-105-015]
Set CNG send time interval
Some machines on the receiving side may not be able to automatically switch the
3-second CNG interval.
High order bit
3000-2250ms: 3000-50xNms
3000 – 50 x Nms 0F (3000 ms) N FF (2250 ms)
0-7
Low order bit
00-0E(3000-3700ms: 3000+50xNms
3000 – 50 x Nms 0F (3000 ms) N 0F (3700 ms)
G3 Switch 0F [SP No. 1-105-016]
No FUNCTION COMMENTS
0
Alarm when an error occurred
in Phase C or later
0: Disabled
1: Enabled
If the customer wants to hear an alarm after each
error communication, change this bit to “1”.
1
Alarm when the handset is
off-hook at the end of
communication
0: Disabled
1: Enabled
If the customer wants to hear an alarm if the
handset is off-hook at the end of fax
communication, change this bit to “1”.

Table of Contents