Laser Optics
D023/D025 4-46 SM
3. Polygon mirror motor holder [A] ( x 2)
4. Polygon mirror motor [B] ( x 4, x 1)
After installing the polygon mirror motor:
1. Do the "Forced Line Position Adj. Mode c" (SP2-111-3).
2. Then do the "Forced Line Position Adj. Mode a" (SP2-111-1).
To check if SP 2-111-1 was successful, watch the screen during the process. A message is
displayed at the end. Also, you can check the result with SP 2-194-10 to -12.
After you replace the motor, do the adjustments in the following section of the manual:
Image Adjustment – Registration.