SC Tables
D023/D025 3-12 SM Appendix
No. Type Details (Symptom, Possible Cause, Troubleshooting Procedures)
220 D Laser synchronizing detection error: start position [K]: LD0
222 D Laser synchronizing detection error: start position [Y]: LD0
226 D Laser synchronizing detection error: start position [C]: LD0
The laser synchronizing detection signal for the start position of the
LDB [K], [Y], [C] is not output for two seconds after LDB unit turns on
while the polygon motor is rotating normally.
Disconnected cable from the laser synchronizing detection unit or
defective connection
Defective laser synchronizing detector
Defective LDB
Defective BICU
- -
1. Check the connectors.
2. Replace the laser-synchronizing detector.
3. Replace the LDB.
4. Replace the BICU.
No. Type Details (Symptom, Possible Cause, Troubleshooting Procedures)
FGATE ON error: K
The PFGATE ON signal does not assert within 5 seconds after
processing the image in normal job or MUSIC for start position [K].
Defective ASIC (Lupus)
Poor connection between controller and BICU.
Defective BICU
230 D
1. Check the connection between the controller board and the BICU.
2. Replace the BICU.
3. Replace the controller board.