SC Tables
D023/D025 3-18 SM Appendix
No. Type Details (Symptom, Possible Cause, Troubleshooting Procedures)
364 D TD sensor (Vt low) error 2: K
365 D TD sensor (Vt low) error 2: M
366 D TD sensor (Vt low) error 2: C
367 D TD sensor (Vt low) error 2: Y
The Vt value of the black, magenta, cyan, or yellow TD sensor is below
the specified value with SP3020-004 (default: 0.5V) for 10 counts.
TD sensor harness disconnected, loose, defective
A drawer connector disconnected, loose, defective
TD sensor defective
- -
1. Check the black, magenta, cyan, or yellow TD sensor connector
and harness between the TD sensor and PCU for damage.
2. Check the drawer connector.
3. Replace the defective PCU.