System Service Mode
D023/D025 8-10 SM Appendix
078 Special 3: BW: Simplex *ENG
079 Special 3: BW: Simplex: Ends *ENG
080 Special 3: BW: Duplex *ENG
081 Special 3: BW: Duplex: Ends *ENG
Target Temp. After Ready *ENG
[140 to 165 / 155 / 1 deg/step]
082
Specifies the target temperature for the maintain mode after the machine has
reached the target temperature in warm-up mode.
Recovery Target Temp. *ENG
[140 to 160 / 150 / 1 deg /step]
083
Specifies the target temperature for the print mode without printing/copying job
after the machine's recovery.
087 Thick 2: FC: Simplex: Ends *ENG
088 Thick 2: BW: Simplex: Ends *ENG
[130 to 180 / 160 / 1 deg/step]
089 Thick 3: FC: Simplex *ENG
090 Thick 3: FC: Simplex: Ends *ENG
091 Thick 3: BW: Simplex *ENG
092 Thick 3: BW: Simplex: Ends *ENG
[135 to 180 / 165 / 1 deg/step]
110 Middle Thick: FC: Duplex *ENG
111 Middle Thick: BW: Simplex *ENG
112 Middle Thick: BW: Duplex *ENG
113 Middle Thick: FC: Simplex: Ends *ENG
114 Middle Thick: FC: Duplex: Ends *ENG
115
Middle Thick: BW: Simplex:
Ends
*ENG
[130 to 175 / 160 / 1 deg/step]