System Service Mode
D023/D025 8-12 SM Appendix
142 Glossy: Plain1 *ENG
143 Glossy: Plain1: Ends *ENG
[120 to 160 / 135 / 1 deg/step]
144 Glossy: Plain2 *ENG
145 Glossy: Plain2: Ends *ENG
[120 to 160 / 140 / 1 deg/step]
146 Glossy: Middle Thick *ENG
147 Glossy: Middle Thick: Ends *ENG
[120 to 160 / 145 / 1 deg/step]
148 1bin: Plain *ENG
149 1bin: Plain: Ends *ENG
[100 to 160 / 140 / 1 deg/step]
150 F: 1bin: Plain *ENG
151 F: 1bin: Plain: Ends *ENG
[100 to 160 / 125 / 1 deg/step]
[Fusing Temperature Display] Fusing Temperature Display (Heating or
Pressure)
1106
Displays the current temperature of the heating and pressure rollers.
001 Fusing: Center -
[–20 to 250 / 0 / 1 deg/step]
The heating roller has two lamps. One
heats the center of the heating roller and
the other heats both ends of the heating
roller.
002 Fusing: Ends -
003 Pressure -
[–10 to 250 / 0 / 1 deg/step]
The heating roller has two lamps. One heat
s the center of the heating roller and the
other heats both ends of the heating roller.