System Service Mode
D023/D025 8-174 SM Appendix
[Execution Interval: Setting]
3511
Adjusts the threshold for each adjustment mode.
001 Job End: Potential Control: BW *ENG
[0 to 2000 / 250 / 1 page/step]
002 Job End: Potential Control: FC *ENG
[0 to 2000 / 100 / 1 page/step]
003 Interrupt: Potential Control: BW *ENG
[0 to 2000 / 500 / 1 page/step]
004 Interrupt: Potential Control: FC *ENG
[0 to 2000 / 200 / 1 page/step]
005 Initial: Potential Control: BW *ENG
[0 to 2000 / 250 / 1 page/step]
006 Initial: Potential Control: FC *ENG
[0 to 2000 / 100 / 1 page/step]
007 Vsg Adj. Counter *ENG
008 Charge AC Control Counter *ENG
[0 to 2000 / 0 / 1 page/step]
009 Interrupt: Vtref Correction: BW *ENG
010 Interrupt: Vtref Correction: FC *ENG
011 Initial: Vtref Correction: FC *ENG
012 Initial: Vtref Correction: BW *ENG
[0 to 2000 / 100 / 1 page/step]
013
Job End: Vt Line Speed
Correction: FC
*ENG
014
Job End: Vt Line Speed
Correction: BW
*ENG
[0 to 2000 / 1000 / 1 page/step]
015
Interrupt: Vt Line Speed
Correction: BW
*ENG
016
Interrupt: Vt Line Speed
Correction: FC
*ENG
[0 to 2000 / 0 / 1 page/step]