System Service Mode
SM Appendix 8-177 D023/D025
Appendix
SP Mode
Tables
[Execution Interval: Display]
3515
Displays the current interval for process control execution.
When the machine calculates the timing for process control, it uses a number
of conditions. These are the results after considering all the conditions.
001 Job End: Potential Control: BW *ENG
[0 to 2000 / 500 / 1 page/step]
002 Job End: Potential Control: FC *ENG
[0 to 2000 / 200 / 1 page/step]
003 Interrupt: Potential Control: BW *ENG
[0 to 2000 / 500 / 1 page/step]
004 Interrupt: Potential Control: FC *ENG
[0 to 2000 / 200 / 1 page/step]
[Refresh Mode] DFU
3516
While making prints with low coverage, the developer is agitated with less
toner consumption and the toner carrier attraction tends to increase. This may
cause low image density or poor transfer (white dots). To prevent this, the
coagulated toner or overcharged toner has to be consumed by performing the
refresh mode.
001 Dev. Motor Rotation: Display: Bk *ENG
002 Dev. Motor Rotation: Display: M *ENG
003 Dev. Motor Rotation: Display: C *ENG
004 Dev. Motor Rotation: Display: Y *ENG
[0 to 1000 / 0 / 0.1 m/step]
005 Rotation Threshold *ENG
[0 to 1000 / 1 / 1 m/step]