System Service Mode
D023/D025 8-200 SM Appendix
[Digital AE Set] DFU
4460
Specifies the level of deleting the background in the ADS mode. You can adjust
its level for each scanning method (platen, ADF).
001 Lower Limit *ENG
[0 to 1023 / 364 / 4 digit/step]
002 Background Level *ENG
[512 to 1532 / 932 / 1 digit/step]
[ACC Target Density]
4501
Selects the ACC result.
001 Copy: Bk: Text *ENG
002 Copy: C: Text *ENG
003 Copy: M: Text *ENG
004 Copy: Y: Text *ENG
005 Copy: Bk: Photo *ENG
006 Copy: C: Photo *ENG
007 Copy: M: Photo *ENG
008 Copy: Y: Photo *ENG
[0 to 10 / 5 / 1 /step]
10: Darkest density