2 Command System RIGOL
DS2000E Programming Guide
:MEASure:RDELay:SMAXimum
:MEASure:RDELay:SMINimum
:MEASure:RDELay:SCURrent
:MEASure:RDELay:SAVerage
:MEASure:RDELay:SDEViation
Syntax 1
:MEASure:RDELay:SMAXimum <chanA>,<chanB>
:MEASure:RDELay:SMINimum <chanA>,<chanB>
:MEASure:RDELay:SCURrent <chanA>,<chanB>
:MEASure:RDELay:SAVerage <chanA>,<chanB>
:MEASure:RDELay:SDEViation <chanA>,<chanB>
Description 1
Enable the delay (rising edge-rising edge) measurement function between the two specified channels and
the statistic function of the measurement results.
Syntax 2
:MEASure:RDELay:SMAXimum? <chanA>,<chanB>
:MEASure:RDELay:SMINimum? <chanA>,<chanB>
:MEASure:RDELay:SCURrent? <chanA>,<chanB>
:MEASure:RDELay:SAVerage? <chanA>,<chanB>
:MEASure:RDELay:SDEViation? <chanA>,<chanB>
Description 2
Query the statistic maximum value (SMAXimum), minimum value (SMINimum), current value (SCURrent),
average value (SAVerage), or standard deviation (SDEViation) of the delay (rising edge-rising edge)
measurement results when the delay (rising edge-rising edge) measurement function between the two
specified channels and the statistic function of the measurement results are enabled.
Parameter
Name Type Range Default
<chanA> Discrete {CHANnel1|CHANnel2} --
<chanB> Discrete {CHANnel1|CHANnel2} --
Return Format
The query returns the statistic maximum value, minimum value, current value, average value, or standard
deviation of the delay (rising edge-rising edge) measurement results in scientific notation. When the
measurement results are invalid, the query returns 9.9e37.